← Job queueWO-10482

Replace failed drive-end bearing

CONV-A12 · Packaging line conveyor · Packaging · Bay 3

CriticalIn progress

Procedure

CONV bearing change — drive end

SOP-MECH-221 · Rev C

Craft

Mechanical

Source

Plant SOP · offline cache

Progress

0/5 · 0%

Reported symptom

Loud growling at drive end; line tripping on over-temp after 12 minutes of run.

Step 1 of 5

Safety gate required

Isolate and lock out the conveyor

Stop CONV-A12 from the local HMI. Open disconnect D-A12 at MCC-3. Apply personal lock and tag. Attempt a start from the local station to verify zero energy.

Why it matters

Unexpected motion during bearing work is a crush hazard.

Tools / materials

  • Personal lock + tag
  • Voltage tester (verify attempt only)

Expected result

HMI shows STOPPED; local start attempt does nothing.

Safety gate · Energy isolation

LOTO verified

Confirm disconnect D-A12 is open, your lock is on the hasp, and a start attempt produced no motion.

Safety confirmation unlocks the next action.